LITHOS 5
Pre-insulated metal panels with mineral fiber insulation for roofs (also available in the version with perforated internal support).
Dimensions
width mm 1000
length upon request from continuous production process.
Standard insulating thickness
mm 50 - 60 - 80 - 100 - 120 - 150 - 200 panels of non standard thicknesses can be supplied upon request previous agreement on minimum quantities.
Supports
galvanized steel, galvanized prepainted or plastified steel; stainless steel; natural or prepainted aluminium; copper (CORAM).
Isulation
made by a special configuration insulating layer, in high-density mineral fibers (λ = 0,040 W/mK), arranged perpendicular to the plate plane.
Protective treatments for external support available
On request for external polyester coating, atoxic prepainted for food contact, silicone polyester, PVDF, thermoplastic Class A application of PVC plastic films or other films.
EPD certification (CAM)
The entire range of roofing and wall panels in steel and aluminium in PIR, PUR and mineral wool, single metal sheet panels and corrugated metal sheets in steel and aluminium, possess the EPD type III - EN ISO 14025 certification, meeting the requirements of compliance with the regulation construction DM 23 June 2022, and satisfying the required CAM criteria.
Mod. EVO joint
Last generation joint in the ECOLINE family, by its very rigid nature and with a high thermal break, does not require special plastic joints to hold the sheets, since the monolithicity is guaranteed by the perfect adhesion obtained with exclusive patented technologies. In particularly critical situations, a simple expanded gasket is used.
Reaction to fire
A2,s1-d0 - on normal unperforated panel, drilling does not allow this classification.
Available on request |
high density mineral fibers |
MODELLO / MODEL |
SPESSORE / THICKNESS |
RISULTATO / RESULT |
CLASSE / RATE |
Lithos |
50 |
REI30 |
A2-s1,d0 |
Lithos |
80 |
REI60 |
A2-s1,d0 |
Lithos |
100 |
REI120 |
A2-s1,d0 |
Lithos (Micro perforated) |
150 |
REI120 |
- |
Fire behavior from outside
BROOF (EN 13501-1)
Fire behavior from outside for roofs
CWFT (ENV 1187)
LOADS TABLE
PITCH BETWEEN SUPP.(m)
PANEL TICKNESS(mm)
SHEET TICKNESS(mm)
MATERIAL
MAXIMUM UNIFORMLY DISTRIBUTED LOAD (daN/m2) - DEFLECTION * |
---|
Panel Thickness (mm) | Material | Sheet thickness (mm) | Pitch 'L' in meters between the supports |
---|
|
2,00 |
2,50 |
3,00 |
3,50 |
4,00 |
4,50 |
5,00 |
5,50 |
6,00 |
---|
50 | ACCIAIO | 0,6 + 0,5 |
164 |
105 |
73 |
54 |
41 |
32 |
26 |
22 |
18 |
60 | ACCIAIO | 0,6 + 0,5 |
192 |
123 |
85 |
63 |
48 |
38 |
31 |
25 |
21 |
80 | ACCIAIO | 0,6 + 0,5 |
363 |
232 |
161 |
119 |
91 |
72 |
58 |
48 |
40 |
100 | ACCIAIO | 0,6 + 0,5 |
404 |
323 |
224 |
165 |
126 |
100 |
81 |
67 |
56 |
120 | ACCIAIO | 0,6 + 0,5 |
438 |
351 |
265 |
195 |
149 |
118 |
96 |
79 |
66 |
150 | ACCIAIO | 0,6 + 0,5 |
460 |
370 |
284 |
215 |
161 |
127 |
100 |
83 |
69 |
200 | ACCIAIO | 0,6 + 0,5 |
465 |
375 |
290 |
220 |
169 |
149 |
112 |
94 |
82 |
MAXIMUM UNIFORMLY DISTRIBUTED LOAD (daN/m2) - DEFLECTION * |
---|
Panel Thickness (mm) | Material | Sheet thickness (mm) | Pitch 'L' in meters between the supports |
---|
|
2,00 |
2,50 |
3,00 |
3,50 |
4,00 |
4,50 |
5,00 |
5,50 |
6,00 |
---|
50 | ACCIAIO | 0,6 + 0,5 | 171 | 97 | 60 | 40 | 28 | 20 | 15 | 12 | 9 |
60 | ACCIAIO | 0,6 + 0,5 | 216 | 125 | 79 | 53 | 37 | 27 | 20 | 15 | 12 |
80 | ACCIAIO | 0,6 + 0,5 | 281 | 213 | 193 | 135 | 99 | 75 | 59 | 47 | 38 |
100 | ACCIAIO | 0,6 + 0,5 | 326 | 252 | 205 | 173 | 148 | 113 | 89 | 71 | 59 |
120 | ACCIAIO | 0,6 + 0,5 | 359 | 277 | 225 | 189 | 164 | 137 | 108 | 87 | 61 |
150 | ACCIAIO | 0,6 + 0,5 | 370 | 288 | 239 | 203 | 175 | 149 | 120 | 93 | 64 |
200 | ACCIAIO | 0,6 + 0,5 | 378 | 296 | 250 | 215 | 186 | 155 | 133 | 105 | 78 |